Siemens Usb Ppi Cable Driver

USB/PPI interface,programming cable for Siemens S7-200PLC,replace 6ES7 901-3DB30-0XA0
  1. Siemens Usb Ppi Multi-master Cable Driver
  2. Siemens Usb Ppi Cable Driver Windows 10
  3. Siemens Usb Ppi Cable Driver Download
  4. Siemens Usb Ppi Multi-master Cable Driver Download

We have a SIMATIC FIELD PG and want to connect to a PLC 200 via the V4.0 STEP 7 MicroWin SP9 via a PC / PPI cable. The problem is that we lost the cable driver, Where can we find it? Our operating system is Windows 7.- Split from USB/PPI Multi-Master Cable 6ES7 901-3DB30-0XA0. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators. Using a standard USB PPI communication cable for downloading a program from the PC to the Siemens S7 200 CPU using Windows 7 and MicroWinFor all your automat.

New OEM Siemens S7-200 USB-PPI PLC Programming cable

Siemens Usb Ppi Cable Driver

Introduction
USB/PPI programming cable simulates USB port as traditional serial port (usually COM3), which enables existing programming software(STEP7-MicroWin) to communicate through simulated traditional port and PLC
devices.
The working power of this cable is from USB port,not provided by the communication port of PLC.The LED of the adapter indicates the sending and receiving status of data.


USB/PPI is applied to Siemens S7-200 PLC,NOT support hot plug.For the industry scene of strong interference and easily destroying communication port,

pls choose optoelectronic isolated USB/PPI+ programming cable.


USB/PPI principle and figure structure:

PINSignalDescription
3RxD/TxD+Data signal B(RS485+)
8RxD/TxD-Data signal A(RS485-)
5GNDGND

Pin signal definition

Functions
● Support Windows2000/Windows XP
● Support STEP7 Micro/WIN V3.2 and higher
● Fully compatible with USB V1.1 and USB CDC V1.1
● Power supply by USB main line.current:about 50mA.
● Baud rate: 300bps ~ 1Mbps
● Support long distance communication up to 2000m
● Working temperature -20~+75'C
● Length 3 meters.Color:black
● One pc supports one USB programming cable only

System requirement
Please make sure your PC is IBM PC compatible and has the following
system requirements before using the USB programming cable.
● Intel is compatible with 586DX4-100MHz CPU or higher
● A standard USB port (4-pin A plug)
● Operating system is Windows2000 or Windows XP

The setting of driver procedure
Please set the driver procedure according to the following steps:
1. Turning on PC power that will connect the USB programming cable and make sure the USB port working well.
2. Put the USB programming cable into USB port and Windows will detect the device and help to add new hardware and jump to new device setting.
Insert the driver CD and click “next” to continue, or select the driver on the hard disk.
If Windows does not show “find new hardware”, please click “Universal Serial bus controllers” in the hardware list of device manager, and choose the USB
device with question mark. Click the right key of mouse and operate to update driver procedure.

If insert the driver CD,you should select the recommended item and click “Next”

If the driver is saved on the hard disk, you should select the second item and click “Next”. You can find the driver on the “WIN” folder.

3. Windows will detect the setting information, and load the driver toinstall.

4. Continue to set up, copy the driver procedure files to your hard disk by Windows.

5. When Windows appears “Completing the Found New Hardware Wizard”, click “finish” to end setting up.

6. After setting up, please make sure the 'port (COM and LPT)' of 'Start Settings Control Panel system hardware Device Manager' appears
'CP2101 USB to UART Bridge Controller(COMx)'. This COMx is the COM message of the USB programming cable.

From then on, as long as you insert the programming cable, the COM port will appear.

You just have to choose this COM port in application software such as programming software or communication software.

The deletion of driver procedure
Deleting driver procedure is to discharge source of COM port so that other
device can be used. When driver procedure has error, it should be deleted and reset up. Please delete the driver procedure as follows:
1. Unplug the USB programming cable from you PC.
2. Choose “USB Serial Converter Drivers”from 'Add or Delete Programs” in operation panel, and click the “Change/Remove” button.

How to change COM setting
1. Delete the driver procedure of all USB to UART products to discharge COM port source, and reset up USB programming cable driver procedure.

The device manager will display the cable address COM3.
2. In Windows 2000/XP the COM slogan can be changed directly. Please double click COM port device that is need changing in the device manager,
and the device attribute information window will appear. Choose “port setting” as the picture shows. Click 'Advanced' button,

and the advanced setting information window will appear. Set the COM port to the serial number you want and click 'OK' button to complete.

Setting of Step 7-MicroWin

Open the main windows form(Step7-MicroWin), click “Set PG/PC Interface” of the left view and will appear PG/PC setting window.

1.Double click “PC/PPI cable(PPI) ” to open COM port and PPI port parameter setting dialog box.

2.Click “Local Connection” to set COM port parameter, choose correctly COM port in the device manager after install the driver,

and set the transmission rate as 9600bps or 19200bps,which is both OK, then the USB/PPI will adapt the baud rate automatic.

About Long Distance Communication
For USB/PPI, the largest communication distance is up to 2000m at the communication speed of 9600bps.

It needs to splice 120ohm terminal resistance between 3 and 8 pin on the RS485 port(DB9 Male) to eliminate signal reflection.

But requires one PFB-G for each PLC.

Notes and Troubleshoot
1. If the USB programming cable could not be detected when opening the PC, or some other outstanding issues occur, please replug it again.
2.USB to UART is plug and play USB device. When data are being transmitted,please don’t disconnect it.
3. Sometimes when Windows System failures or outstanding issues when plug or unplug the USB cable occur, please restart the computer and PLC.
4. USB/PPI cable don’t support “USB” interface in the Step7-MicroWin,so you should choose “COM” port.
5. If the COM port with “*” symbol in the software,such as “*COM3”,it indicates this COM port is at fault,pls exit programming software and then replug the USB port or reinstall the USB driver.
6. It doesn’t support 187.5Kbps baud rate.

Rejection provision
This document is to provide information, and the contents will not be noticed when revising. Because of the direct or indirect loss or errors caused by revised document,

Siemens Usb Ppi Multi-master Cable Driver

will not be the responsibility of the manufacturer.

Package Includes:
OEM Siemens S7-200 USB PPI PLC Cable X 1

USB/PPI cable is suitable for the Siemens S7-200 full range of PLCs. It is a programming cable that provides serial connection and RS485 signal conversion and PPI protocol conversion via USB interface.
The driver control running in the computer simulates the USB interface of the computer into a traditional serial port (commonly known as the COM port), thereby using various existing programming software, communication software, and monitoring software. The working power is taken from the USB port and is not powered by the programming port of the PLC. The two-color LED on the converter box indicates the data transmission and reception status. For industrial sites with high interference and easy to damage the communication port, opto-isolated USB/PPI+ programming cable is selected.

USB/PPI cable characteristics and technical indicators:

1. Support USB/PPI operating system: Windows2000/WindowsXP (WinNT4/95/98/Me/DOS is not supported)
2. Support USB/PPI programming software version: STEP7 Micro/WIN V3.2 and above
3. Fully compatible with USB V1.1 and USB CDC V1.1 specifications
4.USB bus power supply, current consumption is about 50mA
5. Baud rate: 9.6kbps standard baud rate automatically adapts
6. Support UART data format
7. Data bits: 8
8. Stop bits: 1, 2
9. Check digit: odd/even/no parity
10. Support the maximum communication distance of 2KM (9600bps)
11. Only one USB programming cable is supported per PC

Siemens Usb Ppi Cable Driver Windows 10

USB/PPI cable usage:

Siemens Usb Ppi Cable Driver Download

The USB/PPI programming cable needs to be installed with the USB device driver. These drivers are included on the CD that ships with the product. For the installation method, please refer to the documentation on the driver CD, which will not be described here.
After the driver installation is completed, the COM port corresponding to the USB/PPI programming cable will appear in the device manager of Windows. Simply select the COM port in the programming software or other application software, and the next use is the same as the traditional RS232. The port programming cable is identical. It should be noted here that the programming cable does not support the “USB” option of the local communication port setting in the programming software.

Siemens Usb Ppi Multi-master Cable Driver Download

USB/PPI cable long distance communication:

The maximum communication distance between the USB/PPI programming cable and the PLC can reach 2KM (9600bps). In this case, a 120Ω termination resistor should be connected between the 3rd and 8th pins of the RS485 port of the cable (DB9 Male) to eliminate signal reflection. The PFB-G bus isolator is installed on the PLC side, and the communication line adopts a shielded twisted pair with a cross-sectional area of ​​0.22 mm2 or more. More than 2000 meters distance can be added to the bus to add RS485 repeater to extend the communication distance.